MIL-S-11141F
4.4.3.1 Classification of defects. (See inspection data list IDL11-18-3
for inspection equipment required to perform the examinations prescribed in
this section,)
(a)Smoke pot, oil, SGF2, M6 (Dwg D11-18-3).
Categories
Defects
Acceptance standards
Critical
None defined
AQL 0.65 percent defective
Major:
101
Compartment leakage (filled)
4.4.4.1(b)
AQL 1.0 percent defective
Major:
102
Component missing or incorrectly
assembled
103
Screen holes misaligned
104
Vent hole missing (Dwg C11-9-62)
105
Length to offset incorrect
(Dwg C11-9-57)
106
Length (0.656) incorrect
(Dwg C11-9-57)
107
Length incorrect (Dwg D11 -9-66)
108
Matchhead mixture covered
l
with shellac
109
Length (2.61) incorrect
(Dwg C11-9-62)
110
Filling weight incorrect
4.4.4.3
111
Workmanship (3.8)
112
Fuel block and nozzle clearance
4.4.4.2
Minor:
AQL 2.5 percent defective
201
Marking missing, illegible
or incorrect
202
Protective finish marred to
bare metal or incorrect
203
Torque in fuze incorrect
6