MIL-R-51015C(EA)
( b ) Packaging (SPI PMIL-R-51015).
Sampling and
Inspection
acceptance criteria
method
Characteristic
Category
None defined
Critical:
Major
4.2.4.3
Table I, level IX
Unit pack container leakage
101
Item completely clean and dry prior
102
Visual
Table I, level VI
to unit packing
103
Contents per container evident and
Visual
Table I, level VI
correct
104
Unit pack container and closure
Visual
Table I, level VI
evident and correct
Exterior coating on cans evident and
105
Visual
Table I, level Vl
correct
Visual
Table I, level VI
106
Side seam of can striped
Tape closure for bottle evident and
107
Visual
Table I, level VI
correct
108
Packing container and closure evident
Visual
correct
Table I, level VI
Visual
Table I, level VI
Packing assembly evident and correct
109
Visual
Table I, level VI
Marking evident, correct, and legible
110
4.2.3.3 For destructive tests. The Riot Control Agent, CS in the filled capsules taken
in 4.2.2.2 shall be tested as specified in 4.2.4.1.
4.2.4 Tests. Tests shall be conducted as follows:
4.2.4.1 Particle size. Weigh to the nearest 0.01 g approximately 8 g of the Riot Control
Agent, CS and place into an 840-micrometer (No. 20) sieve conforming to RR-S-366
nested into a bottom pan. Cover the sieve and shake by hand for 3 minutes. Weigh the
material in the bottom pan to the nearest 0.01 g. The difference between the initial and final
weighings shall not exceed 0.03 g.
4.2.4.2 Weight. Weigh the filled capsule on a balance which has an accuracy of no less
than 0.001 g.
4.2.4.3 Unit pack container leakage. The unit pack container (can) containing the Riot
Control Agent, CS shall not leak when tested in accordance with method 5009.2 of FED.
TEST METHOD STD. NO. 101 using the hot water technique.
6